Støttemur (Spunt og Micropæler) (SKI)
KU-STM-0000-05
12 måneders intervall
Aktivitetsnummer: 1000
Oppgavebeskrivelse
Påse at ankerhode (med beskyttelsesmaling) er fri for korrosjon.Kommentar
Kommentar:Protection system
Concern limit: When blisters, rust stains, cracks or peeling are detected in protective paint on more than 5% of the surface of the structural element.
Critical limit: When blisters, rust stains, cracks or peeling are detected in protective paint on more than 15% of the surface of the structural element.
In general, paints will be identical to the original used for work. If advances in technology so dictate, other types of paint can be used by checking that they are compatible with the original one.
Metal rust
Concern limit: metal areas with moderate corrosion.
Critical limit: corrosion over the entire metal surface, or on very important parts of it.
Dokumentreferanse
Østfoldbanen V L (Oslo S) - Ski, Ski Stasjon, Underbygning, Permanent spunt, Støttemurer og Støyskjermer, FDV Brukerhåndbok, Km 23,090-25,880- Intervall 12 md
- Myndighetsnivå Lav
- Type FV TK-V
Aktivitetsnummer: 1010
Oppgavebeskrivelse
Påse at beskyttelsemaling og oppheng er fri for korrosjon.Kommentar
Dok.ref:Replacement of damaged protection:
- Removal of the damaged paint layer (it can
become necessary to go all the way down
to the metal, if the defect is deep).
- Preparation of the substrate
- Application of new paint in layers.
Østfoldbanen V L (Oslo S) - Ski, Ski Stasjon, Underbygning, Permanent spunt, Støttemurer og Støyskjermer, FDV Brukerhåndbok, Km 23,090-25,880
Kommentar:
Concern limit: When blisters, rust stains, cracks, or peeling are detected in protective paint on more than 5% of the surface of the structural element.
Critical limit: When blisters, rust stains, cracks, or peeling are detected in protective paint on more than 15% of the surface of the structural element.
In general, paints will be identical to the original used for work. If advances in technology so dictate, other types of paint can be used by checking that they are compatible with the original one.
Dokumentreferanse
Østfoldbanen V L (Oslo S) - Ski, Ski Stasjon, Underbygning, Permanent spunt, Støttemurer og Støyskjermer, FDV Brukerhåndbok, Km 23,090-25,880- Intervall 12 md
- Myndighetsnivå Lav
- Type FV TK-V
Aktivitetsnummer: 1020
Oppgavebeskrivelse
Påse at jordingskabler og -klemmer er fri for skader og korrosjon, samt at det er elektrisk kontakt. Rengjør ved behov.Kommentar
Kommentar:Concern limit: some connectors have moderate corrosion
Critical limit: connectors that have broken off
Dokumentreferanse
Østfoldbanen V L (Oslo S) - Ski, Ski Stasjon, Underbygning, Permanent spunt, Støttemurer og Støyskjermer, FDV Brukerhåndbok, Km 23,090-25,880- Intervall 12 md
- Myndighetsnivå Lav
- Type FV TK-V
Aktivitetsnummer: 1030
Oppgavebeskrivelse
Påse at frostbeskyttelsesskum og brannhemmende maling er i orden, fri for skader og slitasje.Kommentar
Kommentar:Insulation foam:
Concern limit: When blisters, rust stains, cracks or peeling are detected in the insulating foam on more than 15% of the surface of the structural element.
Critical limit: When blisters, rust stains, cracks or peeling are detected in the insulating foam on more than 25% of the surface of the structural element.
Fire retardant paint:
Concern limit: When blisters, rust stains, cracks or peeling are detected in the protective paint on more than 5% of the surface of that element.
Critical limit: When blisters, rust stains, cracks or peeling are detected in the protective paint on more than 15% of the surface of that element.
Dokumentreferanse
Østfoldbanen V L (Oslo S) - Ski, Ski Stasjon, Underbygning, Permanent spunt, Støttemurer og Støyskjermer, FDV Brukerhåndbok, Km 23,090-25,880- Intervall 12 md
- Myndighetsnivå Lav
- Type FV TK-V
120 måneders intervall
Aktivitetsnummer: 1040
Oppgavebeskrivelse
Påse at støttemuren er i posisjon, i orden og fri for skader.Dokumentreferanse
Generic routine KU-STM-0000-01- Intervall 120 md
- Myndighetsnivå Lav
- Type FV TK-V
Aktivitetsnummer: 1050
Oppgavebeskrivelse
Vurder behov for bytte av frostbeskyttelsesskum og brannhemmende maling.Kommentar
Dok.ref:Dette er en visuell kontroll(TK-VE) som kan ende i en periodisk overhaling- utskifting(PO). Østfoldbanen V L (Oslo S) - Ski, Ski Stasjon, Underbygning, Permanent spunt, Støttemurer og Støyskjermer, FDV Brukerhåndbok, Km 23,090-25,880
Kommentar:
Longevity can be extended if they are well preserved for their estimated life. The extension of the service life will be made based on data collected in the inspections performed and is reflected in the Maintenance Plan.
If replacement is required, the GRC panels in the lightweight walls must be removed before performing any working on the sheet piles.
- Intervall 120 md
- Myndighetsnivå Lav
- Type FV TK-V