Branndører i høy- og lavspenningsrom, dørtype T13(BLIX)
EL-DPO-0000-06
1 måneders intervall
Aktivitetsnummer: 1000
Oppgavebeskrivelse
Påse at silikafiberpakninger og gasstett/ forsegling er uten skade og slittasje. Ødelagte pakninger eller pakninger som "strammer" eller ikke passer lenger byttes ut.Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Silica fiber gaskets. Damaged fiber gaskets (i.e. that do not fit
or tighten) should be replaced
or tighten) should be replaced
- Gas tight/weather tight seal. Damaged gaskets (i.e. that do not
fit or tighten) should be replaced
fit or tighten) should be replaced
- Intervall 1 md
- Myndighetsnivå Høy
- Type FV TK-VE
2 måneders intervall
Aktivitetsnummer: 1010
Oppgavebeskrivelse
Påse at døren(e) lar seg åpne 90 grader. Press høykvalitets fett inn i smøreniplene vha smørepistol. Tørk vekk overflødig fett.Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Hinges. Lubrication with high quality grease. Check that door
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
- Door closer. Check the screws that secure the door closer and arm
door/frame and screw that connects the door closer and the arm.
door/frame and screw that connects the door closer and the arm.
- Door co-ordinator. All screws/nuts properly tightened. Lubricant
oil/spray added to moveable joints/parts
oil/spray added to moveable joints/parts
- Panic bar. Lubricate all moveable joints and springs with
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
- Intervall 2 md
- Myndighetsnivå Høy
- Type FV TK-VE
Aktivitetsnummer: 1020
Oppgavebeskrivelse
Påse at skruene som fester dørpumpen til karmen og armen til døren er tilskrudd.Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Hinges. Lubrication with high quality grease. Check that door
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
- Door closer. Check the screws that secure the door closer and arm
door/frame and screw that connects the door closer and the arm.
door/frame and screw that connects the door closer and the arm.
- Door co-ordinator. All screws/nuts properly tightened. Lubricant
oil/spray added to moveable joints/parts
oil/spray added to moveable joints/parts
- Panic bar. Lubricate all moveable joints and springs with
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
- Intervall 2 md
- Myndighetsnivå Høy
- Type FV TK-VE
Aktivitetsnummer: 1030
Oppgavebeskrivelse
Påse at alle skruer og mutre tilknyttet dørkoordinatoren og panikkbaren er skikkelig tiltrukket. Smør bevegelige deler, ledd og fjærer med smøreolje/spray.Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Hinges. Lubrication with high quality grease. Check that door
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
- Door closer. Check the screws that secure the door closer and arm
door/frame and screw that connects the door closer and the arm.
door/frame and screw that connects the door closer and the arm.
- Door co-ordinator. All screws/nuts properly tightened. Lubricant
oil/spray added to moveable joints/parts
oil/spray added to moveable joints/parts
- Panic bar. Lubricate all moveable joints and springs with
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
- Intervall 2 md
- Myndighetsnivå Høy
- Type FV TK-VE
Aktivitetsnummer: 1040
Oppgavebeskrivelse
Påse at selvlysende tape og skilt på panikkbeslag sitter godt. Er tapen skadet eller mangler; Sett på en ny selvlysende tape.Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Hinges. Lubrication with high quality grease. Check that door
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
- Door closer. Check the screws that secure the door closer and arm
door/frame and screw that connects the door closer and the arm.
door/frame and screw that connects the door closer and the arm.
- Door co-ordinator. All screws/nuts properly tightened. Lubricant
oil/spray added to moveable joints/parts
oil/spray added to moveable joints/parts
- Panic bar. Lubricate all moveable joints and springs with
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
- Intervall 2 md
- Myndighetsnivå Høy
- Type FV TK-VE
Aktivitetsnummer: 1050
Oppgavebeskrivelse
Påse at dørpumpe, dørkoordinator og panikkbar fungerer etter hensikten. Juster lukkekraft og lukkehastighet om nødvendigKommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Hinges. Lubrication with high quality grease. Check that door
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
opens 90 degrees, add grease in the grease nipple with the grease gun
and make sure that all redundant grease is removed
- Door closer. Check the screws that secure the door closer and arm
door/frame and screw that connects the door closer and the arm.
door/frame and screw that connects the door closer and the arm.
- Door co-ordinator. All screws/nuts properly tightened. Lubricant
oil/spray added to moveable joints/parts
oil/spray added to moveable joints/parts
- Panic bar. Lubricate all moveable joints and springs with
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
lubricant oil/spray. Ensure that luminescent tape and/or sign on panic
fitting is firmly attached, if it is damaged or removed replace it
with a new one. All sign to be properly cleaned and all screws to be tightened.
- Intervall 2 md
- Myndighetsnivå Høy
- Type FV TK-F
6 måneders intervall
Aktivitetsnummer: 1060
Oppgavebeskrivelse
Påse at tettingen mellom karm og vegg er inntaktKommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Seal between the frame and the wall and/or threshold in mastic compound
- Door sign. Ensure it is clean and readable. Damaged sign to be replaced
- Vision panel. Clean and check for visual damage. Damaged/broken
glass to be replaced immediately
glass to be replaced immediately
- Painting. Check surface treatment of door. Damaged to be repaired
to avoid corrosion problems. Defined requirement for maintenance of
surface protection; not exceed 2 mm
to avoid corrosion problems. Defined requirement for maintenance of
surface protection; not exceed 2 mm
- Handle, lock case and striker plate. Control the latch bolt and
dead bolt. Cleaned with a dry cloth and supply lubrication oil into
the lock case. Light and medium duty handles should be checked for
damage and cleaned with a dry, clean cloth and screws tightened. The
striker plate in the doorframe should be cleaned with a clean, dry
cloth and screws tightened and if necessary adjusted.
dead bolt. Cleaned with a dry cloth and supply lubrication oil into
the lock case. Light and medium duty handles should be checked for
damage and cleaned with a dry, clean cloth and screws tightened. The
striker plate in the doorframe should be cleaned with a clean, dry
cloth and screws tightened and if necessary adjusted.
- Stretching latch system. System should be cleaned and all
screws/nuts properly tightened
screws/nuts properly tightened
- Automatic flush bolt. Bolt should be cleaned with a clean, dry
cloth and supply some lubricant oil/spray into the lock case. All
screws properly tightened.
cloth and supply some lubricant oil/spray into the lock case. All
screws properly tightened.
- Flush bolt. Bolt should be cleaned with a clean, dry cloth and
supply lubricant oil/spray to the flush bolt arm (moveable parts). All
screws properly tightened
supply lubricant oil/spray to the flush bolt arm (moveable parts). All
screws properly tightened
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-V
Aktivitetsnummer: 1070
Oppgavebeskrivelse
Påse at dør-vindu er uten skade og at overflatebehandligen på døra er intaktKommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Seal between the frame and the wall and/or threshold in mastic compound
- Door sign. Ensure it is clean and readable. Damaged sign to be replaced
- Vision panel. Clean and check for visual damage. Damaged/broken
glass to be replaced immediately
glass to be replaced immediately
- Painting. Check surface treatment of door. Damaged to be repaired
to avoid corrosion problems. Defined requirement for maintenance of
surface protection; not exceed 2 mm
to avoid corrosion problems. Defined requirement for maintenance of
surface protection; not exceed 2 mm
- Handle, lock case and striker plate. Control the latch bolt and
dead bolt. Cleaned with a dry cloth and supply lubrication oil into
the lock case. Light and medium duty handles should be checked for
damage and cleaned with a dry, clean cloth and screws tightened. The
striker plate in the doorframe should be cleaned with a clean, dry
cloth and screws tightened and if necessary adjusted.
dead bolt. Cleaned with a dry cloth and supply lubrication oil into
the lock case. Light and medium duty handles should be checked for
damage and cleaned with a dry, clean cloth and screws tightened. The
striker plate in the doorframe should be cleaned with a clean, dry
cloth and screws tightened and if necessary adjusted.
- Stretching latch system. System should be cleaned and all
screws/nuts properly tightened
screws/nuts properly tightened
- Automatic flush bolt. Bolt should be cleaned with a clean, dry
cloth and supply some lubricant oil/spray into the lock case. All
screws properly tightened.
cloth and supply some lubricant oil/spray into the lock case. All
screws properly tightened.
- Flush bolt. Bolt should be cleaned with a clean, dry cloth and
supply lubricant oil/spray to the flush bolt arm (moveable parts). All
screws properly tightened
supply lubricant oil/spray to the flush bolt arm (moveable parts). All
screws properly tightened
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-V
Aktivitetsnummer: 1080
Oppgavebeskrivelse
Påse at håndtak, slagplate og sluttplate i dørkarmen er rengjort og uten skader. Rengjør låsebolt og dødbolt og smør låsekassen.Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Visual inspection of:
- Seal between the frame and the wall and/or threshold in mastic compound
- Door sign. Ensure it is clean and readable. Damaged sign to be replaced
- Vision panel. Clean and check for visual damage. Damaged/broken
glass to be replaced immediately
glass to be replaced immediately
- Painting. Check surface treatment of door. Damaged to be repaired
to avoid corrosion problems. Defined requirement for maintenance of
surface protection; not exceed 2 mm
to avoid corrosion problems. Defined requirement for maintenance of
surface protection; not exceed 2 mm
- Handle, lock case and striker plate. Control the latch bolt and
dead bolt. Cleaned with a dry cloth and supply lubrication oil into
the lock case. Light and medium duty handles should be checked for
damage and cleaned with a dry, clean cloth and screws tightened. The
striker plate in the doorframe should be cleaned with a clean, dry
cloth and screws tightened and if necessary adjusted.
dead bolt. Cleaned with a dry cloth and supply lubrication oil into
the lock case. Light and medium duty handles should be checked for
damage and cleaned with a dry, clean cloth and screws tightened. The
striker plate in the doorframe should be cleaned with a clean, dry
cloth and screws tightened and if necessary adjusted.
- Stretching latch system. System should be cleaned and all
screws/nuts properly tightened
screws/nuts properly tightened
- Automatic flush bolt. Bolt should be cleaned with a clean, dry
cloth and supply some lubricant oil/spray into the lock case. All
screws properly tightened.
cloth and supply some lubricant oil/spray into the lock case. All
screws properly tightened.
- Flush bolt. Bolt should be cleaned with a clean, dry cloth and
supply lubricant oil/spray to the flush bolt arm (moveable parts). All
screws properly tightened
supply lubricant oil/spray to the flush bolt arm (moveable parts). All
screws properly tightened
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-V
Aktivitetsnummer: 1090
Oppgavebeskrivelse
Påse at sluttplaten er korrekt justertKommentar
Dok.ref:Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-V
Aktivitetsnummer: 1100
Oppgavebeskrivelse
Automatic flush bolt (hvis montert); Rengjør og tilfør litt smøreolje/ spray i låsekassenKommentar
Dok.ref:Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-V
Aktivitetsnummer: 1110
Oppgavebeskrivelse
Flush bolt (hvis montert); Rengjør og tilfør litt smøreolje/ spray i låsekassenKommentar
Dok.ref:Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-V
Aktivitetsnummer: 1120
Oppgavebeskrivelse
Gjennomfør en full funksjonstest av døren(e)Kommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Funksjonstest av:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Funksjonstest av:
- Låsebolt og dødbolt
- Strekklåssystem
- Automatisk spylebolt (låst lås er låst i posisjon når aktivt
dørblad er lukket)
dørblad er lukket)
- Skyllebolt
- Topp- og bunnruller. Hvis døren ikke lukkes jevnt og ordentlig,
støy/dissonans, sjekk og fjern om nødvendig sand, støv og skitt
støy/dissonans, sjekk og fjern om nødvendig sand, støv og skitt
- Dørbrems. Funksjonskontroll av dørbrems, døren skal være åpen til
helt åpen posisjon (og lukket) bremsen vil bryte dørens lukkefase.
Lukkehastigheten kan justeres med og justeringsskrue
helt åpen posisjon (og lukket) bremsen vil bryte dørens lukkefase.
Lukkehastigheten kan justeres med og justeringsskrue
Functional test of:
- Latch bolt and dead bolt
- Stretching latch system
- Automatic flush bolt (dead bolt is locked in position when active
door leaf is closed)
door leaf is closed)
- Flush bolt
- Top and bottom-rollers. If the door does not close smooth and
properly, noise/dissonance, check and if necessary, remove sand, dust
and dirt
properly, noise/dissonance, check and if necessary, remove sand, dust
and dirt
- Door brake. Functional operation check of door brake, the door to
be open to full open position (and closed) the brake will break the
doors closing phase. The closing speed can be adjusted with and
adjusting screw
be open to full open position (and closed) the brake will break the
doors closing phase. The closing speed can be adjusted with and
adjusting screw
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV TK-F
Aktivitetsnummer: 1130
Oppgavebeskrivelse
Periodisk overhaling av 3-punkts lås. Dekkplaten skal fjernes, låsesystemet rengjøres og alle skruer/mutre skal strammes skikkeligKommentar
Dok.ref:
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Periodic overhaul of heavy duty 3-point lock.
Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Periodic overhaul of heavy duty 3-point lock.
Cover plate should be removed, latch system cleaned and all
screws/nuts properly tightened
screws/nuts properly tightened
- Intervall 6 md
- Myndighetsnivå Høy
- Type FV PO
60 måneders intervall
Aktivitetsnummer: 1140
Oppgavebeskrivelse
Periodisk utskifting av "mastikkforbindelsen"Kommentar
Dok.ref:Rapp Bomek maintenance manual Dokument ID: 1065 - UFB-30-A-65774 Follobanen, Blixtunnelen, Åsland og Vevelstad, Byggteknisk, Utrustning av tekniske rom I tunnel, FDV brukerhåndbok, Km 2,050 – 22,384 ¿[R7]
Kommentar:
Periodic replacement of the mastic compound
- Intervall 60 md
- Myndighetsnivå Høy
- Type FV PO